This page provides ISO fundamental deviations for hole tolerance positions from D to U for hole sizes over 500 mm up to 3150 mm. Deviation values are given in micrometres (µm), where 1 µm = 0.001 mm.
The fundamental deviation determines the position of the hole tolerance zone relative to the basic (nominal) size. The tolerance grade, such as IT6 or IT7, determines the width of the tolerance zone. Together, the letter and grade form a hole tolerance designation such as H7, K7 or P7.
For holes, ES is the upper deviation and EI is the lower deviation. These deviations are measured from the basic size, represented by the zero line.
A positive deviation places the corresponding hole limit above the basic size, while a negative deviation places it below the basic size. For an H hole, the lower deviation EI = 0.
Select the row containing the basic hole size and then read the fundamental deviation for the required hole tolerance position. The IT tolerance grade is used with the fundamental deviation to determine the complete upper and lower dimensional limits.
Need help using this table? See How to Use ISO 286 Tolerance and Fit Tables for worked examples showing how hole fundamental deviations and IT grades are used to calculate maximum and minimum hole sizes.
| Over | Up to and including | Fundamental Deviation EI (µm) | Fundamental Deviation ES (µm) | ||||||||||||
| D | E | F | G | H | JS | K | M | N | P | R | S | T | U | ||
| 500 | 560 | 260 | 145 | 76 | 22 | 0 | IT/2 | 0 | -26 | -44 | -78 | -150 | -280 | -400 | -600 |
| 560 | 630 | 260 | 145 | 76 | 22 | 0 | IT/2 | 0 | -26 | -44 | -78 | -155 | -310 | -450 | -660 |
| 630 | 710 | 290 | 160 | 80 | 24 | 0 | IT/2 | 0 | -30 | -50 | -88 | -175 | -340 | -500 | -740 |
| 710 | 800 | 290 | 160 | 80 | 24 | 0 | IT/2 | 0 | -30 | -50 | -88 | -185 | -380 | -560 | -840 |
| 800 | 900 | 320 | 170 | 86 | 26 | 0 | IT/2 | 0 | -34 | -56 | -100 | -210 | -430 | -620 | -940 |
| 900 | 1000 | 320 | 170 | 86 | 26 | 0 | IT/2 | 0 | -34 | -56 | -100 | -220 | -470 | -680 | -1050 |
| 1000 | 1120 | 350 | 195 | 98 | 28 | 0 | IT/2 | 0 | -40 | -66 | -120 | -250 | -520 | -780 | -1150 |
| 1120 | 1250 | 350 | 195 | 98 | 28 | 0 | IT/2 | 0 | -40 | -66 | -120 | -260 | -580 | -840 | -1300 |
| 1250 | 1400 | 390 | 220 | 110 | 30 | 0 | IT/2 | 0 | -48 | -78 | -140 | -300 | -640 | -960 | -1450 |
| 1400 | 1600 | 390 | 220 | 110 | 30 | 0 | IT/2 | 0 | -48 | -78 | -140 | -330 | -720 | -1050 | -1600 |
| 1600 | 1800 | 430 | 240 | 120 | 32 | 0 | IT/2 | 0 | -58 | -92 | -170 | -370 | -820 | -1200 | -1850 |
| 1800 | 2000 | 430 | 240 | 120 | 32 | 0 | IT/2 | 0 | -58 | -92 | -170 | -400 | -920 | -1350 | -2000 |
| 2000 | 2240 | 480 | 260 | 130 | 34 | 0 | IT/2 | 0 | -68 | -110 | -195 | -440 | -1000 | -1500 | -2300 |
| 2240 | 2500 | 480 | 260 | 130 | 34 | 0 | IT/2 | 0 | -68 | -110 | -195 | -460 | -1100 | -1650 | -2500 |
| 2500 | 2800 | 520 | 290 | 145 | 38 | 0 | IT/2 | 0 | -76 | -135 | -240 | -550 | -1250 | -1900 | -2900 |
| 2800 | 3150 | 520 | 290 | 145 | 38 | 0 | IT/2 | 0 | -76 | -135 | -240 | -580 | -1400 | -2100 | -3200 |
| over | Up to ( Incl.) |
D | E | F | G | H | JS | K | M | N | P | R | S | T | U |
| Fundamental Deviation (El ) | Fundamental Deviation (Es ) | ||||||||||||||
The fundamental deviation locates the tolerance zone relative to the basic hole size. The appropriate IT grade must then be used to determine the width of the tolerance zone and calculate the maximum and minimum permitted hole dimensions.
For an H hole, EI = 0, so the minimum hole size is equal to the basic size. The upper limit is obtained by adding the appropriate IT tolerance width.