Roymech engineering encyclopedia

Steel Column Buckling to BS EN 1993-1-1:2022 – Eurocode 3


This page provides an engineering reference for the flexural buckling resistance of steel compression members using the second-generation Eurocode 3, BS EN 1993-1-1:2022, Eurocode 3: Design of steel structures – General rules and rules for buildings.

The method relates the elastic critical buckling resistance of a member to its cross-section resistance through a non-dimensional slenderness and an appropriate Eurocode buckling curve. The resulting reduction factor is used to determine the design buckling resistance of the compression member.

UK Eurocode transition: BS EN 1993-1-1:2022 and the corresponding second-generation UK National Annex have been published. However, BSI states that during the transition period the first-generation Eurocodes remain the applicable standards for buildings and civil engineering works constructed in the UK until 30 March 2028, unless otherwise specified by the relevant authority or project specification. Engineers should therefore establish which Eurocode generation and National Annex apply to the particular project before carrying out the design.
Looking for classical or legacy column calculations? See Column and Strut Buckling for Euler theory, Rankine-Gordon and Perry-Robertson methods together with legacy BS 449 design information.

Relevant Standards

Standard Application
BS EN 1993-1-1:2022 Eurocode 3 – Design of steel structures. General rules and rules for buildings. Includes the second-generation rules for compression-member buckling.
NA to BS EN 1993-1-1:2022 UK National Annex to the second-generation BS EN 1993-1-1:2022. Published in 2026 and containing UK Nationally Determined Parameters where applicable.

The applicable National Annex and project specification should always be consulted when the Eurocode permits nationally determined values.

Compression Member Buckling

A compression member can become unstable and buckle before the material reaches its cross-section resistance. Buckling resistance depends on the member length, restraint conditions, cross-section properties, material strength and the relevant mode of instability.

For ordinary flexural buckling, both principal axes should normally be considered. Open or asymmetric sections can also be susceptible to torsional or torsional-flexural buckling and require the corresponding Eurocode checks.

Eurocode 3 Design Route

For a concentrically loaded compression member subject to flexural buckling, the basic procedure is:

  1. Determine the design compressive force NEd.
  2. Determine the cross-section properties and cross-section classification.
  3. Establish the relevant buckling length Lcr for each buckling plane.
  4. Calculate the elastic critical buckling force Ncr.
  5. Calculate the relative slenderness.
  6. Select the appropriate Eurocode buckling curve.
  7. Determine the imperfection factor α.
  8. Calculate the buckling reduction factor χ.
  9. Calculate the design buckling resistance Nb,Rd.
  10. Verify that the design compression force does not exceed the design buckling resistance.

Elastic Critical Buckling Force

For an ideal prismatic member undergoing elastic flexural buckling, the Euler critical force is:

Ncr = π2 E I Lcr 2

where:

  • Ncr = elastic critical force for the relevant buckling mode
  • E = Young's modulus
  • I = second moment of area about the relevant buckling axis
  • Lcr = buckling length in the plane being considered

The critical force must be calculated about the relevant axis. The lowest applicable buckling resistance will normally govern the member design.

Buckling Length

The buckling length Lcr represents the length of an equivalent pin-ended member having the same elastic critical buckling resistance. It depends on the member restraint and the behaviour of the surrounding structure.

For simple idealised cases it is often expressed as:

Lcr = k L

where k is an effective-length factor and L is the physical member length.

Do not select an effective-length factor solely from an idealised end-condition sketch when analysing a real structure. The actual rotational and translational restraint, frame stability and interaction with adjoining members must be considered. Elastic critical analysis of the structure may be required.

Relative Slenderness

BS EN 1993-1-1:2022 defines the relative slenderness for the relevant buckling mode from the characteristic compression resistance and elastic critical force:

λ¯ = NRk Ncr

where:

  • NRk = characteristic compression resistance of the cross-section
  • Ncr = elastic critical force for the relevant buckling mode

Class 1, 2 and 3 Cross-Sections

For Class 1, Class 2 and Class 3 cross-sections subject to flexural buckling, the relative slenderness may also be expressed as:

λ¯ = Lcr i λ1

where:

  • i = radius of gyration about the relevant axis
  • λ1 = reference slenderness

The reference slenderness is:

λ1 = π E fy

where fy is the yield strength appropriate to the steel and product thickness.

Class 4 Cross-Sections

For Class 4 cross-sections, local plate buckling affects the effective cross-sectional properties. The effective area Aeff therefore has to be taken into account when determining the characteristic compression resistance and relative slenderness.

The appropriate effective-section rules of Eurocode 3 should be used rather than applying the gross-area equations for Class 1, 2 or 3 sections without modification.

Buckling Curves and Imperfection Factors

Real compression members do not behave as perfect Euler columns. Geometric imperfections, residual stresses and section behaviour reduce the practical buckling resistance. Eurocode 3 represents these effects using a series of buckling curves.

BS EN 1993-1-1:2022 uses the following imperfection factors for the standard flexural buckling curves:

Buckling Curve Imperfection Factor α
a0 0.13
a 0.21
b 0.34
c 0.49
d 0.76

The appropriate buckling curve is selected from the Eurocode according to factors including section type, manufacturing method, dimensions, steel strength and the axis about which buckling occurs.

Do not choose the buckling curve from the imperfection factor alone. Use the section-specific buckling-curve selection rules in the applicable edition of BS EN 1993-1-1 and its National Annex.

Buckling Reduction Factor

For flexural buckling, the reduction factor χ is determined from:

χ = 1 Φ + Φ2 − λ¯ 2

with:

Φ = 0.5 [ 1 + α ( λ¯ − 0.2 ) + λ¯ 2 ]

with the limitation:

χ ≤ 1.0

where:

  • χ = buckling reduction factor
  • α = imperfection factor for the selected buckling curve
  • λ̄ = relative slenderness

Design Buckling Resistance

The design buckling resistance of a compression member is:

Nb,Rd = χ NRk γM1

where:

  • Nb,Rd = design buckling resistance
  • χ = reduction factor for the relevant buckling mode
  • NRk = characteristic compression resistance
  • γM1 = partial factor for member instability

The value of γM1 must be taken from the applicable Eurocode and National Annex.

Class 1, 2 and 3 Cross-Sections

For a uniform Class 1, Class 2 or Class 3 cross-section in axial compression:

NRk = A fy

and therefore:

Nb,Rd = χ A fy γM1

Class 4 Cross-Sections

For Class 4 cross-sections the effective area is used:

NRk = Aeff fy

The corresponding effective-section provisions and any eccentricity arising from an asymmetric effective section must also be considered.

Buckling Resistance Verification

The compression-member buckling check is expressed as:

NEd Nb,Rd ≤ 1.0

where NEd is the design value of the compressive axial force.

The check must be performed for each relevant buckling mode, with the governing resistance used for design.

Low Relative Slenderness

BS EN 1993-1-1:2022 permits the compression-member buckling verification to be omitted where:

λ¯ ≤ 0.2

or where:

NEd ≤ 0.04 Ncr

The cross-section resistance and all other applicable design requirements still have to be satisfied.

Flexural, Torsional and Torsional-Flexural Buckling

Flexural buckling is not necessarily the only instability mode that must be considered. Members with open, singly symmetric or asymmetric cross-sections can have a lower resistance in torsional or torsional-flexural buckling.

For such members, the appropriate elastic critical force and relative slenderness for torsional or torsional-flexural buckling should be determined in accordance with Eurocode 3. The corresponding reduction factor is then used in the member resistance check.

This page is primarily a flexural-buckling reference. Do not assume that checking flexural buckling about the two principal axes is sufficient for every steel section or restraint arrangement.

Combined Compression and Bending

A member subjected to significant bending in addition to axial compression is a beam-column rather than a purely axially loaded column. The simple compression buckling check on this page is then insufficient.

The appropriate Eurocode interaction rules for combined axial force and bending moments must be applied, together with any required second-order effects and global stability analysis.

Important Design Considerations

  • Check buckling about every relevant axis and consider torsional or torsional-flexural instability where applicable.
  • Use the correct steel yield strength for the steel grade and product thickness.
  • Determine the cross-section class before selecting the resistance properties.
  • Use effective cross-section properties where required for Class 4 sections.
  • Establish realistic member restraints and buckling lengths from the structural system.
  • Use the buckling curve specified for the section type, manufacturing method, steel strength and buckling axis.
  • Consider second-order effects where required by the structural analysis.
  • Check combined compression and bending where moments are present.
  • Consider local buckling, connection behaviour and load introduction in addition to overall member buckling.
  • Use the National Annex applicable to the country and project concerned.

Classical Buckling Theory and Legacy Design

The Eurocode method retains a clear relationship with classical Euler buckling theory through the elastic critical force Ncr. However, practical steel-member resistance is reduced to account for imperfections, residual stresses, cross-section behaviour and other effects not represented by the ideal Euler column.

For Euler buckling theory, Rankine-Gordon calculations, Perry-Robertson methods and legacy BS 449 information, see:

Column and Strut Buckling – Euler, Rankine and Perry-Robertson

Related RoyMech References

Standards References

  • BS EN 1993-1-1:2022 – Eurocode 3: Design of steel structures – General rules and rules for buildings.
  • NA to BS EN 1993-1-1:2022 – UK National Annex to Eurocode 3: Design of steel structures – General rules and rules for buildings.

Standards are revised periodically. The current edition, applicable National Annex and project specification should be confirmed before using this information for design.