This page provides an engineering reference for the flexural buckling resistance of steel compression members using the second-generation Eurocode 3, BS EN 1993-1-1:2022, Eurocode 3: Design of steel structures – General rules and rules for buildings.
The method relates the elastic critical buckling resistance of a member to its cross-section resistance through a non-dimensional slenderness and an appropriate Eurocode buckling curve. The resulting reduction factor is used to determine the design buckling resistance of the compression member.
| Standard | Application |
|---|---|
| BS EN 1993-1-1:2022 | Eurocode 3 – Design of steel structures. General rules and rules for buildings. Includes the second-generation rules for compression-member buckling. |
| NA to BS EN 1993-1-1:2022 | UK National Annex to the second-generation BS EN 1993-1-1:2022. Published in 2026 and containing UK Nationally Determined Parameters where applicable. |
The applicable National Annex and project specification should always be consulted when the Eurocode permits nationally determined values.
A compression member can become unstable and buckle before the material reaches its cross-section resistance. Buckling resistance depends on the member length, restraint conditions, cross-section properties, material strength and the relevant mode of instability.
For ordinary flexural buckling, both principal axes should normally be considered. Open or asymmetric sections can also be susceptible to torsional or torsional-flexural buckling and require the corresponding Eurocode checks.
For a concentrically loaded compression member subject to flexural buckling, the basic procedure is:
For an ideal prismatic member undergoing elastic flexural buckling, the Euler critical force is:
where:
The critical force must be calculated about the relevant axis. The lowest applicable buckling resistance will normally govern the member design.
The buckling length Lcr represents the length of an equivalent pin-ended member having the same elastic critical buckling resistance. It depends on the member restraint and the behaviour of the surrounding structure.
For simple idealised cases it is often expressed as:
where k is an effective-length factor and L is the physical member length.
BS EN 1993-1-1:2022 defines the relative slenderness for the relevant buckling mode from the characteristic compression resistance and elastic critical force:
where:
For Class 1, Class 2 and Class 3 cross-sections subject to flexural buckling, the relative slenderness may also be expressed as:
where:
The reference slenderness is:
where fy is the yield strength appropriate to the steel and product thickness.
For Class 4 cross-sections, local plate buckling affects the effective cross-sectional properties. The effective area Aeff therefore has to be taken into account when determining the characteristic compression resistance and relative slenderness.
The appropriate effective-section rules of Eurocode 3 should be used rather than applying the gross-area equations for Class 1, 2 or 3 sections without modification.
Real compression members do not behave as perfect Euler columns. Geometric imperfections, residual stresses and section behaviour reduce the practical buckling resistance. Eurocode 3 represents these effects using a series of buckling curves.
BS EN 1993-1-1:2022 uses the following imperfection factors for the standard flexural buckling curves:
| Buckling Curve | Imperfection Factor α |
|---|---|
| a0 | 0.13 |
| a | 0.21 |
| b | 0.34 |
| c | 0.49 |
| d | 0.76 |
The appropriate buckling curve is selected from the Eurocode according to factors including section type, manufacturing method, dimensions, steel strength and the axis about which buckling occurs.
For flexural buckling, the reduction factor χ is determined from:
with:
with the limitation:
where:
The design buckling resistance of a compression member is:
where:
The value of γM1 must be taken from the applicable Eurocode and National Annex.
For a uniform Class 1, Class 2 or Class 3 cross-section in axial compression:
and therefore:
For Class 4 cross-sections the effective area is used:
The corresponding effective-section provisions and any eccentricity arising from an asymmetric effective section must also be considered.
The compression-member buckling check is expressed as:
where NEd is the design value of the compressive axial force.
The check must be performed for each relevant buckling mode, with the governing resistance used for design.
BS EN 1993-1-1:2022 permits the compression-member buckling verification to be omitted where:
or where:
The cross-section resistance and all other applicable design requirements still have to be satisfied.
Flexural buckling is not necessarily the only instability mode that must be considered. Members with open, singly symmetric or asymmetric cross-sections can have a lower resistance in torsional or torsional-flexural buckling.
For such members, the appropriate elastic critical force and relative slenderness for torsional or torsional-flexural buckling should be determined in accordance with Eurocode 3. The corresponding reduction factor is then used in the member resistance check.
A member subjected to significant bending in addition to axial compression is a beam-column rather than a purely axially loaded column. The simple compression buckling check on this page is then insufficient.
The appropriate Eurocode interaction rules for combined axial force and bending moments must be applied, together with any required second-order effects and global stability analysis.
The Eurocode method retains a clear relationship with classical Euler buckling theory through the elastic critical force Ncr. However, practical steel-member resistance is reduced to account for imperfections, residual stresses, cross-section behaviour and other effects not represented by the ideal Euler column.
For Euler buckling theory, Rankine-Gordon calculations, Perry-Robertson methods and legacy BS 449 information, see:
Column and Strut Buckling – Euler, Rankine and Perry-Robertson
Standards are revised periodically. The current edition, applicable National Annex and project specification should be confirmed before using this information for design.