Roymech engineering encyclopedia

Fastener Selection Guide – Bolts, Screws and Threaded Joints


Selecting a threaded fastener involves more than choosing a bolt of the right diameter. The engineer must consider the type of fastener, thread system, strength class, applied loads, required preload, tightening method, joint behaviour, thread engagement, risk of loosening and the structure into which the fastener is installed.

This guide provides a route through the RoyMech screw and threaded-fastener references. It is intended particularly for students, apprentices and engineers who need help deciding which information or calculation to use.

Already know what you need? Experienced engineers can go directly to the detailed RoyMech technical references linked throughout this guide.

Fastener Selection Route

1. Choose the Fastener Type

Begin with the function of the connection rather than immediately selecting a bolt diameter.

Common arrangements include:

Arrangement Typical Reason for Selection Consider
Hexagon bolt and nut General through-bolted connection where both sides of the joint are accessible. Access for the nut, washer requirements, grip length and tightening method. Projecting threads and crevices may make a conventional bolt-and-nut arrangement unsuitable for exposed hygienic areas.
Hexagon head screw Fastener screws directly into a tapped component. A blind tapped hole can provide a particularly clean external arrangement where hygienic design is required. Thread engagement, strength of the internally threaded material, spanner access and available blind-hole depth. Particularly useful where exposed threads and recessed fastener heads are undesirable.
Socket head cap screw Useful where radial access is restricted or a compact head is required. Tool access, counterbore dimensions and available material beneath the screw head. The internal hexagon recess can be a contamination or liquid trap and may be undesirable in exposed hygienic areas.
Countersunk screw Selected where a flush surface is required. Countersink geometry and the reduced head loadability of countersunk fasteners.
Stud and nut Useful where repeated dismantling is expected, access favours a stud, or the female thread should remain permanently engaged. Stud installation, thread fit, engagement, nut arrangement and exposed thread where relevant.
Anchor fastener Transfers equipment or structural loads into concrete, masonry or another supporting material. Substrate, edge distance, spacing, embedment, anchor type and structural design.
Engineering practice – hygienic installations: Fastener selection in pharmaceutical, food and other hygienic process environments should consider cleanability as well as mechanical strength.

Where practical, a hexagon head screw installed into a blind tapped hole can provide a cleaner arrangement than a conventional socket-head screw, because there is no internal tool recess in the head and no exposed thread projecting beyond a nut.

Where a through-fastening is required, exposed male threads should also be considered. A suitable dome or cap nut may be used in appropriate applications to enclose the projecting thread and provide a more readily cleanable external surface.

Conventional socket-head screws can be undesirable in exposed hygienic areas because the internal hexagon recess can retain product, dirt or cleaning liquid. Similarly, an ordinary bolt and nut arrangement can leave exposed threads and crevices which are difficult to clean.

The final arrangement should meet the hygienic design, cleanability, material, corrosion-resistance and cGMP requirements applicable to the installation.

For current dimensional information see:

RoyMech also retains legacy dimensional references for engineers working with older machinery and drawings:

2. Choose the Thread

For most general-purpose metric machinery, an ISO metric thread will be the natural starting point. The thread designation establishes features including nominal diameter and pitch.

Coarse or Fine Pitch?

The standard coarse pitch is normally the first choice unless there is a specific reason to use a fine pitch.

Fine-pitch threads may be useful where finer axial adjustment, particular geometry or other design requirements justify them. They should not simply be regarded as a stronger version of a coarse thread: the design needs to consider both the tensile section of the fastener and the behaviour of the engaged threads.

Useful rule: If the drawing or design requirement does not provide a reason for selecting a special pitch, check the preferred ISO metric thread series before creating a non-standard thread.

Use the current RoyMech thread references for new design:

The older RoyMech pages remain available when identifying or maintaining legacy equipment:

Trapezoidal Threads

A normal ISO metric fastening thread should not automatically be used for a power screw or motion-transmission application.

Where the thread is intended to transmit controlled axial motion or substantial axial force through repeated rotation, a trapezoidal thread may be more appropriate.

See: ISO Metric Trapezoidal Screw Threads – Dimensions and Geometry .

3. Select the Fastener Strength or Property Class

Metric steel bolts, screws and studs are commonly identified by a property class such as 8.8, 10.9 or 12.9. The property class is related to the mechanical properties of the fastener material; it is not simply a quality grade.

Selection should consider the required tensile strength, yield or proof behaviour, fastener diameter, joint design and environmental requirements. The mating nut and internally threaded material must also be suitable for the selected fastener.

Do not select a higher property class automatically. A stronger bolt does not correct an inadequate joint, weak female thread, insufficient edge distance, poor tightening procedure or unsuitable material.

Use:

4. Determine the Fastener Loading

The next question is not simply "How much load is on the bolt?" but how is the load applied to the complete joint?

A threaded joint may be subjected to:

  • direct tension;
  • direct shear;
  • combined tension and shear;
  • bending;
  • eccentric loading;
  • fluctuating or fatigue loading;
  • impact or shock;
  • thermal loading;
  • loads tending to separate or slip the clamped components.

For a group of bolts, the total external force should not automatically be divided equally between the fasteners. Eccentric forces and moments can produce substantially different loads in individual bolts.

Use: Bolted Joint Design – Shear, Bearing and Combined Loading for bolt groups, shear, bearing, eccentric loading and combined stress.

5. Determine Preload and Tightening Requirements

A bolted joint normally works by developing tension in the bolt and compression in the clamped components. This initial bolt tension is the preload.

Preload can be fundamental to joint performance. Adequate clamp force can:

  • keep the joint faces in contact;
  • reduce joint separation;
  • allow transverse loads to be resisted by friction where the joint is designed for this;
  • reduce the alternating component of bolt load in some joints;
  • help resist self-loosening by preventing relative movement.

The required preload and the permitted bolt stress must be considered together.

Tightening Torque

Torque is commonly used as an indirect method of producing bolt preload. However, much of the applied tightening torque is consumed in friction in the threads and beneath the rotating nut or bolt head.

Consequently, the relationship between tightening torque and achieved preload depends strongly on friction conditions, lubrication, coatings, surface finish and the fastener system.

A torque value is not a universal property of a bolt size. A quoted tightening torque is meaningful only when its assumptions about fastener strength, desired preload and friction conditions are understood.

Use: Bolt Preload – Joint Stiffness, Tightening Torque and Clamp Force .

For proof-load information and RoyMech's calculated indicative tightening torques see: Bolt Proof Load, Tensile Load and Tightening Torque .

6. Check the Behaviour of the Complete Joint

A common mistake is to analyse the bolt but not the joint.

Once a preloaded joint is assembled, an external tensile load does not necessarily increase the bolt load by the full value of the applied external load. The distribution depends on the relative stiffness of the bolt and the clamped members while the joint remains in contact.

The engineer should therefore consider:

  • bolt stiffness;
  • stiffness of the clamped components;
  • initial preload;
  • external separating load;
  • loss of clamp force;
  • joint separation;
  • slip between mating surfaces;
  • embedment and settlement;
  • fatigue where loading fluctuates.

The RoyMech Bolt Preload page covers the relationship between bolt load, joint stiffness and external loading, while Bolted Joint Design covers the broader joint loading calculations.

7. Check Thread Engagement and Stripping

A sufficiently strong bolt can still produce an inadequate connection if the female thread strips before the required bolt load is developed.

This becomes particularly important where a high-strength steel screw is installed directly into a component manufactured from a weaker material such as aluminium alloy, cast material or some polymers.

The required engagement depends on more than nominal bolt diameter. Relevant factors include:

  • strength of the male thread material;
  • strength of the female thread material;
  • thread pitch;
  • thread geometry;
  • thread tolerances;
  • effective engagement length;
  • required failure mode and design margin.
Avoid universal rules such as "thread engagement = 1D". Such rules can be useful as preliminary workshop guidance in some material combinations, but they are not a substitute for checking thread stripping where the connection is significantly loaded.

Use: Screw Thread Stress Areas, Thread Stripping and Engagement Length .

8. Consider Loosening and Locking

A correctly designed preloaded joint does not automatically require an additional locking device. The first objective should normally be to understand why loosening could occur.

Possible causes include:

  • transverse movement of the joint;
  • insufficient preload;
  • loss of preload through embedment or relaxation;
  • vibration;
  • thermal cycling;
  • rotation of connected components;
  • incorrect tightening;
  • joint settlement.

Where additional locking is justified, the engineer can choose between prevailing-torque arrangements and positive mechanical locking methods.

Examples include:

  • prevailing-torque nuts;
  • jam nuts;
  • castellated nuts and split pins;
  • safety wire;
  • tab washers;
  • locking plates;
  • threadlocking adhesives;
  • special locking thread systems.

Use: Screw and Bolt Locking Methods for the advantages, limitations and engineering considerations associated with these methods.

9. Consider Whether a Stud Is More Appropriate

A stud can be preferable to a screw or bolt in a number of applications. Because the stud can remain installed in the parent component while the nut is removed, repeated maintenance does not necessarily require repeated assembly of the parent thread.

Studs can also assist assembly and component location and are widely used in machinery, pressure-containing equipment, engines, flanged connections and other engineering assemblies.

Weld studs provide a different solution where a threaded attachment is required on a plate or structure without conventional drilling and tapping.

Use: Stud Bolts and Weld Studs – Threaded Studs and Stud Welding .

10. Consider Anchors and the Supporting Structure

When machinery, frames or supports are fixed to a concrete floor, wall or building structure, the problem extends beyond ordinary bolt selection. The anchor must transfer the equipment loads safely into the supporting material.

For machinery foundations and baseplates, the structural engineer may require the complete set of forces and moments:

  • Fx, Fy and Fz;
  • Mx, My and Mz;
  • relevant static and dynamic load cases.

Anchor design can depend on:

  • concrete or masonry strength;
  • cracked or uncracked concrete;
  • anchor type;
  • embedment depth;
  • anchor spacing;
  • edge distance;
  • member thickness;
  • reinforcement;
  • tension and shear interaction;
  • baseplate behaviour;
  • dynamic, fatigue or seismic loading where relevant.

Use: Anchor Fasteners for Concrete Floors, Masonry and Walls .

Quick Guide – Which RoyMech Page Do I Need?

If You Need To... Use This RoyMech Reference
Choose current ISO metric thread dimensions ISO Metric Screw Thread Dimensions
Understand current ISO thread tolerance classes ISO Metric Thread Tolerances
Identify an older metric thread or work from a legacy drawing Legacy ISO Metric Screw Thread Dimensions
Select current hexagon bolt, nut and washer dimensions Current ISO Hexagon Bolts, Nuts and Washers
Identify older BS hexagon fastener dimensions Legacy Hexagon Bolts, Nuts and Washers
Select socket head or countersunk screws Socket Head Cap and Countersunk Screws
Check bolt material strength or property class Fastener Strength and Property Classes
Find proof load, tensile load or an indicative tightening torque Bolt Proof Load, Tensile Load and Tightening Torque
Calculate preload or understand joint stiffness Bolt Preload – Joint Stiffness, Tightening Torque and Clamp Force
Analyse shear, bearing, eccentric or combined bolt loading Bolted Joint Design
Check tensile stress area or thread stripping Screw Thread Stress Areas, Stripping and Engagement Length
Select a method of preventing loosening Screw and Bolt Locking Methods
Use threaded or welded studs Stud Bolts and Weld Studs
Design a power or motion screw ISO Metric Trapezoidal Screw Threads
Fasten machinery to concrete, masonry or a wall Anchor Fasteners for Concrete Floors, Masonry and Walls
Check space required around a bolt head or tool Bolt Head Clearances

A Practical Fastener Design Sequence

For a new mechanical joint, a useful engineering sequence is:

  1. Define what the joint must do. Establish the components being joined, required service life, maintenance requirements, operating environment and consequences of failure.
  2. Determine the loads. Include tension, shear, moments, dynamic loads and relevant load combinations.
  3. Choose the basic fastener arrangement. Decide between bolt and nut, screw into a tapped component, stud, anchor or another arrangement.
  4. Consider the service environment. Check corrosion, temperature, cleanliness, hygiene, contamination control and other application-specific requirements before fixing the fastener form and material.
  5. Select the thread and nominal size. Use preferred standard sizes and pitches wherever practical.
  6. Select the required fastener property class and material. Consider both strength and service environment.
  7. Check the fastener stresses. Consider tensile, shear and combined loading as appropriate.
  8. Check the female thread and engagement. Ensure the parent thread does not become the unintended weak point.
  9. Determine the required preload. Consider joint stiffness, separation, slip and fatigue.
  10. Specify the tightening method. Torque, controlled tensioning or another method should be appropriate to the accuracy required.
  11. Consider loosening and preload loss. Add a locking system where the service conditions or consequences justify it.
  12. Check geometry, access and cleanability. Confirm head clearance, tool access, washer space, edge distances, assembly requirements and, where relevant, whether recesses, exposed threads or crevices create cleaning or contamination problems.
  13. Specify the fastener completely. The final drawing or specification should identify the applicable dimensions, material/property class, finish, thread and any special tightening, locking, cleanliness or installation requirements.
The key principle: A threaded fastener should be selected as part of the complete joint. The bolt, female thread, clamped components, preload, tightening method, locking arrangement, service environment and supporting structure all contribute to whether the connection performs successfully.

Detailed RoyMech Fastener References

Once the appropriate design route has been identified, use the detailed RoyMech technical pages for the dimensions, equations, tables and engineering data required for the calculation or specification.