ISO 3601-2:2025 specifies housing dimensions for O-rings used in general industrial applications. It covers housing arrangements for general hydraulic and pneumatic applications, with or without anti-extrusion (back-up) rings.
The principal housing arrangements covered on this page are radial piston seals, radial rod seals, axial face seals and chamfered-corner static seals. Groove width is additionally influenced by whether anti-extrusion rings are required.
| Housing | O-Ring Location | Typical Application |
|---|---|---|
| Piston | Groove in piston | O-ring seals against the cylinder bore. |
| Rod | Groove in external housing | O-ring seals against the rod surface. |
| Axial / face | Groove in one mating face | Static sealing between mating faces. |
| Chamfered corner | Triangular space formed by a chamfer and mating component | Static sealing at a component corner. |
There are two practical starting points when designing an O-ring housing.
The required O-ring is selected and the surrounding hardware and housing dimensions are then established to suit that seal.
This route is appropriate where the bore or rod dimensions remain flexible.
The bore or rod diameter is already established and an appropriate O-ring and housing arrangement are selected to suit the hardware.
This is common with hydraulic and pneumatic equipment using preferred bore and rod dimensions.
The following notation is used for the principal O-ring and housing dimensions shown on this page.
| Symbol | Description |
|---|---|
| d1 | O-ring inside diameter |
| d2 | O-ring cross-section diameter |
| d3 | Piston groove diameter |
| d4 | Cylinder bore diameter |
| d5 | Rod diameter |
| d6 | Rod housing / groove diameter |
| b1 | Groove width for O-ring without back-up ring |
| b2 | Groove width for O-ring with one back-up ring |
| b3 | Groove width for O-ring with two back-up rings |
| t | Effective radial housing depth |
| h | Axial groove depth |
| g | Radial clearance / potential extrusion gap |
| z | Lead-in chamfer |
In a piston arrangement the O-ring is fitted into a circumferential groove in the piston and seals against the cylinder bore.
For the geometry shown above, nominal radial housing depth is:
The tolerance stack should also be checked:
| Application | Principal Design Considerations |
|---|---|
| Static | Squeeze, groove fill, sealing reliability and extrusion clearance. |
| Pneumatic dynamic | Friction, lubrication, surface finish, squeeze and wear. |
| Hydraulic dynamic | Pressure, friction, extrusion clearance, wear, surface finish and possible use of back-up rings. |
In a rod arrangement the O-ring is installed in the surrounding housing and seals against the outside diameter of the rod.
For the geometry shown above:
For tolerance analysis:
An axial O-ring is compressed between two mating faces rather than between concentric cylindrical components. This arrangement is normally used for static sealing.
Pressure acts from the inside of the sealed diameter towards the outside. The groove should support the O-ring against pressure-induced outward movement.
Pressure acts from outside towards the centre. The groove should support the O-ring against inward movement.
A useful static sealing arrangement is formed by machining a chamfer on one component so that, when the parts are assembled, the chamfer and the adjacent mating surfaces form a substantially triangular housing for the O-ring.
This arrangement can be useful where the component geometry makes a conventional rectangular face groove inconvenient. The O-ring is retained in the space formed by the chamfer and mating component and is compressed as the assembly is brought together.
The design must provide the required O-ring compression while retaining sufficient space for the elastomer to deform. Chamfer geometry, component tolerances and O-ring cross-section therefore have to be considered together.
High pressure or excessive clearance can cause the elastomer to extrude into the gap between mating components. Anti-extrusion (back-up) rings can be used to support the O-ring.
| Width | Arrangement | Typical Use |
|---|---|---|
| b1 | O-ring only | Back-up ring not required. |
| b2 | O-ring + one back-up ring | Pressure acts predominantly from one direction. |
| b3 | Back-up ring + O-ring + back-up ring | Pressure can act from either direction. |
Back-up-ring dimensions and requirements are covered separately by ISO 3601-4.
The radial clearance between mating components forms a potential extrusion gap. Whether a back-up ring is required depends on the interaction between:
Clearance should be checked at the worst combination of component tolerances and operating deflection rather than at nominal dimensions alone.
An O-ring seals because its cross-section is compressed when the components are assembled.
For a radial rectangular housing, nominal percentage squeeze may be expressed as:
where:
A nominal squeeze calculation is not sufficient for a finished engineering design. Minimum and maximum squeeze should be established from the dimensional tolerance stack.
The O-ring must have sufficient housing volume to accommodate its cross-sectional area together with dimensional tolerances, thermal expansion and fluid-induced swelling.
A groove should therefore not be designed solely to obtain the desired squeeze. Groove width and depth together determine the space available to the elastomer.
Lead-in features reduce the risk of cutting, shaving or pinching the O-ring during installation. The required geometry depends on the O-ring cross-section and component arrangement.
The complete installation path should also be checked for:
Where potentially damaging features cannot be avoided, an installation sleeve or other suitable protection should be considered.
Surface texture is particularly important where relative movement occurs between the O-ring and the mating component.
The following surfaces should be considered separately:
For dynamic seals, a surface can be dimensionally correct yet still produce excessive friction, rapid wear or leakage if its surface texture is unsuitable.
| Design Situation | RoyMech Reference |
|---|---|
| New equipment | Use current ISO 3601-1 O-ring dimensional information together with ISO 3601-2:2025 housing requirements. |
| Existing BS 1806 equipment | Retain the original dimensional/housing system where appropriate and use the RoyMech legacy reference. |
| Existing BS 4518 equipment | Establish the original metric O-ring and housing dimensions before substituting a different series. |